This miniature accelerometer model achieves extremely high frequency
response from 5 Hz to 60 kHz, and incorporates a LP filter to avoid
saturation of the output signal to to excessive vibration.
|
|
ENG |
SI |
|
Performance |
|
|
|
Sensitivity (±15 %) |
10 mV/g |
1,02 mV/(m/s²) |
|
Measurement Range [5] |
±500 g pk |
±4905 m/s² pk |
|
Frequency Range (±3 dB) |
5 to 60000 Hz |
5 to 60000 Hz |
|
Electrical Filter Corner Frequency [4] |
45 kHz |
45 kHz |
|
Electrical Filter Roll-off [4] |
10 dB/decade |
10 dB/decade |
|
Resonant Frequency |
≥95 kHz |
≥95 kHz |
|
Broadband Resolution (1) [2] |
0.002 g rms |
0.02 m/s² rms |
|
Non-Linearity [1] |
≤1 % |
≤1 % |
|
Transverse Sensitivity [3] |
≤5 % |
≤5 % |
|
Environmental |
|
|
|
Overload Limit (Shock) |
±5000 g pk |
±49050 m/s² pk |
|
Temperature Range (Operating) |
-65 to +250 °F |
-54 to +121 °C |
|
Temperature Response [2] |
See Graph %/°F |
See Graph %/°F |
|
Base Strain Sensitivity [2] |
0.05 g/µε |
|
|
Electrical |
|
|
|
Excitation Voltage |
18 to 30 VDC |
18 to 30 VDC |
|
Constant Current Excitation |
2 to 20 mA |
2 to 20 mA |
|
Output Impedance |
≤100 Ohm |
≤100 Ohm |
|
Output Bias Voltage |
8 to 12 VDC |
8 to 12 VDC |
|
Discharge Time Constant [4] |
0.02 to 0.06 sec |
0.02 to 0.06 sec |
|
Spectral Noise (10 Hz) [2] |
160 µg/√Hz |
1570 (µm/sec2)/√Hz |
|
Spectral Noise (100 Hz) [2] |
40 µg/√Hz |
390 (µm/sec2)/√Hz |
|
Spectral Noise (1000 Hz) [2] |
15 µg/√Hz |
147 (µm/sec2)/√Hz |
|
Spectral Noise (10 kHz) [2] |
10 µg/√Hz |
98 (µm/sec2)/√Hz |
|
Physical |
|
|
|
Size - Height |
|
21.6 mm |
|
Size - Hex |
3/8 in |
9.53 mm |
|
Weight [2] |
|
6.0 gm |
|
Sensing Element |
Ceramic |
Ceramic |
|
Sensing Geometry |
Shear |
Shear |
|
Housing Material |
Stainless Steel |
Stainless Steel |
|
Sealing |
Welded Hermetic |
Welded Hermetic |
|
Electrical Connector |
5-44 Coaxial |
5-44 Coaxial |
|
Electrical Connection Position |
Top |
Top |
|
Mounting Thread |
10-32 Male |
10-32 Male |
|
Mounting |
Integral Stud |
Integral Stud |
* All specifications are at room temperature unless otherwise specified.
Specification Notes
[1] Zero-based, least-squares, straight line method.
[2] Typical.
[3] Transverse sensitivity is typically ≤ 3%.
[4] Calculated.
[5] >6 mA excitation current required when driving cables longer than 50 ft (15.2 m) to avoid distortion and maintain full range
[6] See PCB Declaration of Conformance PS023 for details.

Accessories
|
Supplied |
||
|
ACS-52 |
Single Axis Amplitude Cal -3dB to +3dB frequency range |
1 |
Optional Versions
(A) Adhesive Mount
|
|
ENG |
SI |
|
Mounting |
Adhesive |
|
|
Mounting Thread |
None - Adhesive Mount Only |
|
|
Size - Hex |
3/8 in |
9.53 mm |
|
Size - Height |
0.68 in |
17.3 mm |
(M) Metric Mount
|
|
ENG |
SI |
|
Mounting Thread |
M6 x 0.75 Male |
|