• dynamic pressure sensors
  • акселерометры
  • испытательное оборудование dewesoft
  • давление и перепад давлений
  • конфигуратор / коммуникатор
  • позиционеры
  • уровень, плотность, граница раздела жидкостей
  • кожух термозащитный подогреваемый
  • нагреваемые шланги teat
  • Accelerometer ICP® Model 352A72

    Miniature, lightweight (0.6 gm), ceramic shear ICP® accel., 10 mV/g, 0.5 to 4.5k Hz,
    titanium housing, built-in 15 kHz LP filter, 10-ft flexible, integral cable.

     

    • Sensitivity: (±15%) 10 mV/g (1.02 mV/(m/s²))
    • Measurement Range: ±500 g pk (±4905 m/s² pk)
    • Broadband Resolution: 0.003 g rms (0.03 m/s² rms)
    • Frequency Range: (±5%) 0.5 to 4500 Hz
    • Sensing Element: Ceramic
    • Weight: 0.64 gm

     

     

    ENG

    SI

    Performance

     

     

    Sensitivity (±15 %)

    10 mV/g

    1.02 mV/(m/s²)

    Measurement Range

    ±500 g pk

    ±4905 m/s² pk

    Frequency Range (±5 %)

    0.5 to 4500 Hz

    0.5 to 4500 Hz

    Electrical Filter Corner Frequency [2]

    15000 Hz

    15000 Hz

    Electrical Filter Roll-off [2]

    6 dB/octave

    6 dB/octave

    Resonant Frequency

    ≥65 kHz

    ≥65 kHz

    Broadband Resolution (1) [2]

    0.003 g rms

    1. 03 m/s² rms

    Non-Linearity [1]

    ≤1 %

    ≤1 %

    Transverse Sensitivity

    ≤5 %

    ≤5 %

    Environmental

     

     

    Overload Limit (Shock)

    ±10000 g pk

    ±98100 m/s² pk

    Temperature Range (Operating)

    -65 to +200 °F

    -54 to +93 °C

    Temperature Response [2]

    See Graph %/°F

    See Graph %/°F

    Electrical

     

     

    Excitation Voltage

    18 to 30 VDC

    18 to 30 VDC

    Constant Current Excitation

    2 to 20 mA

    2 to 20 mA

    Output Impedance

    ≤200 Ohm

    ≤200 Ohm

    Output Bias Voltage

    7 to 12 VDC

    7 to 12 VDC

    Discharge Time Constant

    1.0 to 3.5 sec

    1.0 to 3.5 sec

    Settling Time (within 10% of bias)

    <3 sec

    <3 sec

    Spectral Noise (1 Hz) [2]

    725 µg/√Hz

    7110 (µm/sec2)/√Hz

    Spectral Noise (10 Hz) [2]

    225 µg/√Hz

    2210 (µm/sec2)/√Hz

    Spectral Noise (100 Hz) [2]

    100 µg/√Hz

    981 (µm/sec2)/√Hz

    Spectral Noise (1 kHz) [2]

    100 µg/√Hz

    981 (µm/sec2)/√Hz

    Physical

     

     

    Size - Height

    1. 14 in

    3.6 mm

    Size - Length

    1. 41 in

    10.4 mm

    Size - Width

    1. 25 in

    6.4 mm

    Weight (Without Cable) [2]

    1. 023 oz

    0.64 gm

    Sensing Element

    Ceramic

    Ceramic

    Sensing Geometry

    Shear

    Shear

    Housing Material

    Titanium

    Titanium

    Sealing

    Hermetic

    Hermetic

    Electrical Connector

    Solder pins with attached cable

    Solder pins with attached cable

    Electrical Connection Position

    Side

    Side

    Cable Termination

    10-32 Coaxial Plug

    10-32 Coaxial Plug

    Cable Length [3]

    10 ft

    3 m

    Mounting

    Adhesive

    Adhesive

     

    * All specifications are at room temperature unless otherwise specified.

     

    Specification Notes

     

    [1] Zero-based, least-squares, straight line method.
    [2] Typical.
    [3] Cable is made up of 1 ft. of 089 cable (32 AWG twisted pair) spliced to 9 ft. of 018 cable (coaxial).
    [4] See PCB Declaration of Conformance PS023 for details.

     

     

    Accessories

     

    Supplied

    ACS-1

    Single axis amplitude response calibration from 10 Hz to upper 5% frequency, NIST traceable

    1

    080A109

    Petro Wax, one square, 1" x 1" x 0.25"

    1

    039A32

    Removal tool (for Model 352A71, 352A72)

    1