• dynamic pressure sensors
  • акселерометры
  • испытательное оборудование dewesoft
  • давление и перепад давлений
  • конфигуратор / коммуникатор
  • позиционеры
  • уровень, плотность, граница раздела жидкостей
  • кожух термозащитный подогреваемый
  • нагреваемые шланги teat
  • Charge Output Accelerometer Model 6222S-100A

    Accelerometer, PE, 100 pC/g, -65°F to +500°F, differential output,
    ARINC mount, 60 grams, no cable incl.

     

    • Sensitivity: (±5%) 100 pC/g
    • Measurement Range: 500 g pk
    • Frequency Range: (±5%) 6 kHz
    • Connector: two pin 7/16-27 UNS
    • Weight: 60. gm

     

    Performance

     

    Sensitivity (±5 %)

    100 pC/g

    Measurement Range

    500 g pk

    Frequency Range (±5 %)

    from 1 to 6000 Hz

    Frequency Range (±1 dB)

    from 1 to 9000 Hz

    Resonant Frequency

    ≥28 kHz

    Non-Linearity

    1/200 g

    Transverse Sensitivity

    ≤3 %

    Environmental characteristics

     

    Overload Limit (Shock)

    ±1000 g pk

    Temperature Range (Operating)

    -54 to +260 °C

    Base strain sensitivity

    0.2 equiv g pk /μ strain

    Thermal transient sensitivity

    0.009 equiv. g pk /˚C

    Electrical characteristics

     

    Resistance (Between pins)

    ≥10 GΩ

    At +500˚F (+260˚C)

    ≥50 MΩ

    Isolation (Pin to case)

    ≥10 GΩ

    At +500˚F (+260˚C)

    ≥50 MΩ

    Capacitance

    12000 pF

    Capacitance Either signal pin to case

    ≤30 pF

    Capacitance Unbalance between pins

    ≤2 pF

    Grounding

    Signal return isolated from case

    Physical characteristics

     

    Weight

    60 gm

    Case material

    Stainless steel

    Connector

    Two pin 7/16-27 UNS receptacle

    Mounting torque

    10-32 stud, 2 Nm

     

    * All specifications are at room temperature unless otherwise specified.

     

    Specification Notes

     

    1. Cover resonance at approximately 23 kHz, case resonance at approxiamtely 35 kHz.

    2. Low-end amplitude response is a function of the associated electronics.

    3. Prolonged exposure at maximum temperature may decrease the return to room temperature resistance to as low as 500 MΩ , but will not degrade the overall performance of the unit. All units are processed to initially meet 10 GΩ at room temperature.

    4. Maintain high levels of precision and accuracy using Endevco’s factory calibration services. Call Endevco’s inside sales force at 866-ENDEVCO for recommended intervals, pricing and turn-around time for these services as well as for quotations on our standard products.