Charge output accel, with UHT-12TM shear sensing crystal, 2.3 pC/g,
+1200 F operation, 10-ft int hardline cable with smaller 10-32 coax jack,
with intrinsic safety approvals.
|
|
ENG |
SI |
|
Performance |
|
|
|
Sensitivity (±10 %) |
2.3 pC/g |
|
|
Measurement Range |
±1000 g pk |
±9800 m/s² pk |
|
Frequency Range (±5 %) |
3000 Hz |
3000 Hz |
|
Frequency Range (±1 dB) |
5000 Hz |
5000 Hz |
|
Resonant Frequency |
≥15 kHz |
≥15 kHz |
|
Non-Linearity (per full scale range) |
≤2.5 % |
≤2.5 % |
|
Transverse Sensitivity |
≤5 % |
≤5 % |
|
Environmental |
|
|
|
Overload Limit (Shock) |
±2000 g pk |
±19600 m/s² pk |
|
Temperature Range (Operating) |
-67 to +1200 °F |
-55 to +649 °C |
|
Temperature Range (Survivable Limit) |
-67 to +1400 °F |
-55 to +760 °C |
|
Temperature Range (Cable Termination) |
-67 to +900 °F |
-55 to +482 °C |
|
Temperature Response [1] |
See Graph %/°F |
See Graph %/°F |
|
Radiation Exposure Limit (Integrated Neutron Flux) |
1 E10 N/cm² |
1 E10 N/cm² |
|
Radiation Exposure Limit (Integrated Gamma Flux |
1 E8 rad |
1 E8 rad |
|
Electrical |
|
|
|
Capacitance [1] [2] |
1000 pF |
1000 pF |
|
Insulation Resistance (at 70°F [21°C]) |
≥100 MOhm |
≥100 MOhm |
|
Insulation Resistance (at 1200° F [649°C]) |
≥10 kOhm |
≥10 kOhm |
|
Output Polarity [3] |
Negative |
Negative |
|
Electrical Isolation |
Signal Isolated from Case |
Signal Isolated from Case |
|
Physical |
|
|
|
Sensing Element |
UHT-12™ |
UHT-12™ |
|
Sensing Geometry |
Shear |
Shear |
|
Housing Material |
Inconel |
Inconel |
|
Sealing (Sensor Housing) |
Hermetic |
Hermetic |
|
Sealing (Connector) |
Welded Hermetic |
Welded Hermetic |
|
Size - Height |
|
|
|
Size - Length |
|
24.1 mm |
|
Size - Width |
|
|
|
Weight (without cable) [1] |
1.6 oz |
45 gm |
|
Electrical Connector |
Integral Hardline Cable |
Integral Hardline Cable |
|
Cable Type |
015 Hardline Cable |
015 Hardline Cable |
|
Cable Length |
10 ft |
3.05 m |
|
Cable Termination |
10-32 Coaxial Jack |
10-32 Coaxial Jack |
|
Mounting |
Through Hole |
Through Hole |
* All specifications are at room temperature unless otherwise specified.
Specification Notes
[1] Typical.
[2] Additional cable length will add approx 100pF/ft.
[3] Negative output signal with positive acceleration.
[4] See PCB Declaration of Conformance PS199 for details.

Accessories
|
Supplied |
||
|
081A116 |
Mounting bolt, 10-32 UNJF-3A x 5/8", Inconel 718 |
1 |
|
ACS-1 |
Single axis amplitude response calibration from 10 Hz to upper 5% frequency, NIST traceable |
1 |