Model Endevco 8510B is a rugged, miniature, high sensitivity piezoresistive pressure transducer. It has a 10-32 mounting thread, 0.15 inch (3.8 mm) face diameter and is available in ranges from 1 psi to 2000 psi. Its high sensitivity combined with high resonance makes it ideal for measuring dynamic pressure.
|
Specifications |
|||||||
|
Dynamic characteristics |
Units |
-1 |
-2 |
-5 |
-200 |
-500 |
-2000 |
|
Range |
psig |
0-1 |
0-2 |
0-5 |
0-200 |
0-500 |
0-2000 |
|
Positive sensitivity [1] |
mV/psi |
200 ±50 |
100 +55/-25 |
60 ±20 |
1.5 ±0.5 |
0.6 ±0.2 |
0.15 ±0.05 |
|
Combined: non-linearity, non-repeatability, pressure hysteresis [2] |
% FSO RSS max |
1.50 |
1.50 |
0.75 |
0.50 |
0.50 |
1.0 |
|
Zero measurand output [3] |
mV max |
±10 |
±10 |
±10 |
±10 |
±10 |
±10 |
|
Thermal zero shift from 0˚F to +200˚F (-18˚C to +93˚C) |
±% FSO max |
3 |
3 |
3 |
3 |
3 |
3 |
|
Resonance frequency |
Hz |
55000 |
70000 |
85000 |
320000 |
500000 |
900000 |
|
Warm-up time [5] |
ms |
1 |
1 |
1 |
1 |
1 |
1 |
|
Acceleration sensitivity |
Equiv. psi/g |
0.0002 |
0.0002 |
0.0002 |
0.0003 |
0.0004 |
0.00027 |
|
Burst pressure (diaphragm/reference side) [6] |
psi min |
25/25 |
40/40 |
100/100 |
1000/300 |
2500/300 |
10000/300 |
|
Electrical |
|||||||
|
Full scale output |
300 ±100 mV at 10.0 Vdc; 200 ±50 mV at 10.0 Vdc for 8510 |
||||||
|
Supply voltage |
10.0 Vdc standard, 18.0 Vdc maximum |
||||||
|
Polarity |
Positive output for increasing pressure into (+) port (end with screen on it) |
||||||
|
Resistance Input |
1500 ±600 ohms |
||||||
|
Resistance Output |
1500 ±600 ohms |
||||||
|
Mechanical |
|||||||
|
Case material |
Stainless steel (17-4 PH CRES) |
||||||
|
Cable, integral |
4 conductor No. 32 AWG Teflon® insulated leads, braided shield, silicone jacket, 30 ±3 in (760 ±76 mm) |
||||||
|
Mounting torque |
10-32 UNF-2A threaded case 0.438 inch (11.12 mm) long/15 ±5 lbf-in (1.7 ±0.6 Nm) |
||||||
|
Weight |
2.3 grams (cable weighs 9 grams/meter) |
||||||
|
Environmental |
|||||||
|
Temperature [7] [8] |
-65˚F to +250˚F (-54˚C to +121˚C) |
||||||
|
Vibration |
1000 g pk |
||||||
|
Acceleration |
1000 g |
||||||
|
Shock |
20 000 g, 100 microsecond haversine pulse |
||||||
|
Calibration data: ISO17025 Calibration includes: range, sensitivity, non-linearity, non-repeatability, hysteresis, zero measurand output, zero shift after 3X range, thermal zero shift and thermal sensitivity shift. |
|||||||