• dynamic pressure sensors
  • акселерометры
  • испытательное оборудование dewesoft
  • давление и перепад давлений
  • конфигуратор / коммуникатор
  • позиционеры
  • уровень, плотность, граница раздела жидкостей
  • кожух термозащитный подогреваемый
  • нагреваемые шланги teat
  • Triaxial Charge Output Accelerometer Model 357A67

    Triaxial Charge Accelerometer, 0.40 x 0.45 inch, 3.0 pC/g, M3 thread, 4-pin conn.

     

    • Sensitivity: (±15%) 3.0 pC/g (0.306 pC/(m/s²))
    • Measurement Range: ±1000 g pk (±9800 m/s² pk)
    • Frequency Range: (+10%) 1 to 10000 Hz
    • Temperature Range: -60 to +200 °C
    • Electrical Connector: 1/4-28 4-Pin
    • Weight: 4.9 gm

     

     

    ENG

    SI

    Performance

     

     

    Sensitivity (±15 %)

    3.0 pC/g

    1. 306 pC/(m/s²)

    Measurement Range

    ±1000 g pk

    ±9800 m/s² pk

    Frequency Range (±10 %) (x or y axis) [2/3]

    1 to 10000 Hz

    1 to 10000 Hz

    Frequency Range (±10 %) (z axis) [2/.3]

    1 to 12800 Hz

    1 to 12800 Hz

    Frequency Range (±10 %) (x or y axis) [2/.4]

    1 to 5500 Hz

    1 to 5500 Hz

    Resonant Frequency

    ≥45 kHz

    ≥45 kHz

    Non-Linearity [1]

    ≤2 %

    ≤2 %

    Transverse Sensitivity

    ≤5 %

    ≤5 %

    Environmental

     

     

    Overload Limit (Shock)

    ±5000 g pk

    ±49050m/s² pk

    Temperature Range (Operating)

    -76 to +392 °F

    -60 to +200 °C

    Temperature Range (Survivable Limit)

    -76 to +500 °F

    -60 to +260 °C

    Temperature Response [5]

    See Graph %/°F

    See Graph %/°F

    Base Strain Sensitivity [5]

    0.05 g/µε

    0.5 (m/s²)/µε

    Electrical

     

     

    Capacitance [5]

    650 pF

    650 pF

    Insulation Resistance (at 70° F [21° C])

    >100000000000 Ohm

    >100000000000 Ohm

    Insulation Resistance (at 500° F [260° C]) [5]

    >100000000 Ohm

    >100000000 Ohm

    Electrical Isolation (Case)

    ≥100000000 Ohm

    ≥100000000 Ohm

    Output Polarity [6]

    Negative

    Negative

    Physical

     

     

    Sensing Element

    Ceramic

    Ceramic

    Sensing Geometry

    Shear

    Shear

    Housing Material

    Titanium

    Titanium

    Sealing

    Hermetic

    Hermetic

    Size - Length

    1. 78 in

    19.8 mm

    Size - Width

    1. 45 in

    11.4 mm

    Size - Height

    1. 40 in

    10.2 mm

    Weight [3]

    1. 17 oz

    4.9 gm

    Electrical Connector

    1/4-28 4-Pin

    1/4-28 4-Pin

    Mounting Thread

    M3 x 0.50 Female

    M3 x 0.50 Female

    Mounting Torque

    4 to 5 in-lb

    45 to 55 N-cm

     

    * All specifications are at room temperature unless otherwise specified.

     

    Specification Notes

     

    [1] Zero-based, least-squares, straight line method.

    [2] Low frequency response is determined by external signal conditioning electronics.

    [3] Mounted on base.

    [4] Verified amplitude response during calibration with reduced useful frequency response on the x and y axes due to mounting on a surface other than the base.

    [5] Typical.

    [6] Accel from structure into sensor base.

    [7] See PCB Declaration of Conformance PS158 for details.

     

     

    Accessories

     

    Supplied

    081A134

    Mounting stud, M3 to 10-32, for 357A67

    1

    ACS-1T

    Triaxial amplitude response calibration, from 10 Hz to upper 5% frequency, NIST traceable

    1

    ACS-44T

    Extended Frequency Response Calibration to +10% point on a triax accel, (requires ACS-1T)

    1

    M081A134

    Mounting stud, M3 to M3, for 357A67

    1

    Optional

    523R10

    3-coax, 34 awg (7/42), twisted bundle, low noise, PFA cable, 10-ft, 1/4-28 4-socket, shell isolated plug, 200C rated to triple splice assembly with (3) 4.5-in coaxial cables each with a 10-32 plug (EB) for charge triax sensors

    0