• dynamic pressure sensors
  • акселерометры
  • испытательное оборудование dewesoft
  • давление и перепад давлений
  • конфигуратор / коммуникатор
  • позиционеры
  • уровень, плотность, граница раздела жидкостей
  • кожух термозащитный подогреваемый
  • нагреваемые шланги teat
  • Charge Output Accelerometer Model 357M168

    Extreme Temperature, Miniature Accelerometer with Weld Tabs,
    10 ft hardline cable terminated in a 10-32 (NJ).

     

    • Sensitivity: (±10%) 1.15 pC/g (0.117 pC/(m/s²))
    • Measurement Range: ±1000 g pk (±9800 m/s² pk)
    • Frequency Range: (±10%) 10 kHz
    • Cable Termination: 10-32 Coaxial Jack
    • Weight: 10 gm

     

     

    ENG

    SI

    Performance

     

     

    Sensitivity (±10 %) [1]

    1.15 pC/g

    0.117 pC/(m/s²)

    Measurement Range [1]

    ±1000 g pk

    ±9800 m/s² pk

    Frequency Range (±10 %)

    10000 Hz

    10000 Hz

    Resonant Frequency [2]

    ≥45 kHz

    ≥45 kHz

    Non-Linearity [1]

    ≤1 %

    ≤1 %

    Transverse Sensitivity

    ≤5 %

    ≤3 %

    Environmental

     

     

    Overload Limit (Shock)

    ±2000 g pk

    ±19600 m/s² pk

    Temperature Range (Operating) [3]

    -67 to +1200 °F

    -55 to +649 °C

    Temperature Range (Survivable Limit)

    -67 to +1400 °F

    -55 to +760 °C

    Temperature Range (Cable Termination)

    -67 to +900 °F

    -55 to +482 °C

    Temperature Response [2]

    See Graph %/°F

    See Graph %/°F

    Radiation Exposure Limit (Integrated Neutron Flux)

    1 E10 N/cm²

    1 E10 N/cm²

    Radiation Exposure Limit (Integrated Gamma Flux

    1 E8 rad

    1 E8 rad

    Electrical

     

     

    Capacitance

    1000 pF

    1000 pF

    Insulation Resistance (at 70°F [21°C])

    ≥1 GOhm

    >1 GOhm

    Insulation Resistance (at 1200° F [649°C])

    ≥30 kOhm

    ≥30 kOhm

    Output Polarity

    Positive

    Positive

    Electrical Isolation

    Signal Isolated from Case

    Signal Isolated from Case

    Physical

     

     

    Sensing Element

    UHT-12™

    UHT-12™

    Sensing Geometry

    Shear

    Shear

    Housing Material

    Nickel Alloy

    Nickel Alloy

    Sealing (Sensor Housing)

    Hermetic

    Hermetic

    Sealing (Connector)

    Welded Hermetic

    Welded Hermetic

    Size - Height

    1. 4 in

    10.2 mm

    Size - Length

    1. 55 in

    14.0 mm

    Size - Width

    1. 50 in

    12.7 mm

    Weight [2]

    1. 35 oz

    10 gm

    Electrical Connector

    Integral Hardline Cable

    Integral Hardline Cable

    Cable Length [3]

    10 ft

    3.05 m

    Cable Type

    MI Hardline Cable

    MI Hardline Cable

    Cable Termination

    10-32 Coaxial Jack

    10-32 Coaxial Jack

    Mounting Thread

    5-40 Female

    5-40 Female

     

    * All specifications are at room temperature unless otherwise specified.

     

    Specification Notes

     

    [1] Conversion Factor 1g = 9.81 m/s².

    [2] Typical.

    [3] For cable lengths less than 1.5 Ft [0.46m] insulation resistance is only tested to 900F [482C].

    [4] Additional cable length will add approx. 100pF/ft.

    [5] See PCB Declaration of Conformance PS081 for details.

     

     

    Accessories

    Supplied

    64287-01

     

    1

    ACS-44

    Extended Frequency Response Calibration to +10% point (requires ACS-1)

    1